Specialized process engineering
Design separation equipment and optimize process columns and vessels for chemical and petrochemical applications.
Purpose-designed process equipment
GSD Engineering specializes in designing separation equipment for chemical and petrochemical industries, optimizing process columns and vessels. Proper process design and correct selection of internals are essential for reliable separator performance.
We apply separation science across distillation, absorption and phase separation, benchmarking proven technologies to develop solutions for project operating conditions and material requirements.
Discuss a Separation Study
How we work
Design separation equipment and optimize process columns and vessels for chemical and petrochemical applications.
Apply knowledge of distillation, absorption and phase separation alongside relevant industry standards.
Benchmark global technologies to develop designs suited to project operating conditions and materials.
Coordinate with licensors and fabricators to support integration and dependable operation.
Simulation-led sizing
Using Sep-Calc software from Kirk Process Solutions, we simulate operating conditions across separator configurations to identify a suitable design. Iterative assessment of vessel dimensions and internals helps balance required performance and cost.
Design calculations can include key vessel and internals parameters such as:
Oil & gas separation applications
Internals for two-phase and three-phase separators, scrubbers and knockout drums.
Inlet devices, coalescing elements and mist eliminators for gas-liquid and liquid-liquid separation.
Equipment designed to address varying flow ranges and demanding operating conditions.
Design coordination with proven technologies, EPC contractors and operators to support safe plant operation.
The first step in vessel performance
Inlet devices dissipate momentum and support phase distribution and droplet disengagement inside separators and process columns. Their design affects residence-time effectiveness and the performance of downstream internals.
Process design evaluates inlet momentum flux (ρV²), inlet velocity and flow regime, droplet behaviour and mist formation to inform device selection.
Illustrative process case
Reference design and 1S case values shown in the supplied engineering example.
| Parameter | Unit | Design | 1S | Design |
|---|---|---|---|---|
| Gas mass flow rate | kg/h | 68,795 | 62,541 | 68,795 |
| Gas density | kg/m³ | 12.150 | 12 | 12 |
| Oil mass flow rate | kg/h | 44,612 | 40,556 | 44,612 |
| Oil density | kg/m³ | 770.7 | 771 | 771 |
| Water mass flow rate | kg/h | 430,691 | 391,537 | 430,691 |
| Water density | kg/m³ | 979 | 979 | 979 |
| Pipe ID | m | 0.610 | 0.610 | 0.610 |
| Calculation | Unit | Design | 1S | Design |
|---|---|---|---|---|
| Oil volumetric flow | m³/h | 57.885 | 52.622 | 57.885 |
| Water volumetric flow | m³/h | 439.839 | 399.854 | 439.839 |
| Gas volumetric flow | m³/h | 5,662.15 | 5,147.41 | 5,662.15 |
| Gas superficial velocity | m/s | 5.391618 | 4.901471 | 5.391618 |
| Liquid superficial velocity | m/s | 0.473943 | 0.430858 | 0.473943 |
| Water weight fraction | – | 0.906 | 0.906 | 0.906 |
| Oil weight fraction | – | 0.094 | 0.094 | 0.094 |
| Liquid mixture density | kg/m³ | 954.95 | 954.95 | 954.95 |
| Gas Froude number | FrG | 0.25029 | 0.22753 | 0.25029 |
| Liquid Froude number | FrL | 0.19505 | 0.17732 | 0.19505 |
| Water weight fraction | – | 0.79157 | 0.79157 | 0.79157 |
| Oil weight fraction | – | 0.08199 | 0.08199 | 0.08199 |
| Gas weight fraction | – | 0.12644 | 0.12644 | 0.12644 |
| Mixture density | kg/m³ | 88.329 | 88.329 | 88.329 |
| Mixture velocity | m/s | 5.866 | 5.332 | 5.866 |
| Momentum in pipe | Pa | 3,039.0 | 2,511.5 | 3,039.0 |
Internals selection
Selection balances process conditions, separation targets, equipment constraints and maintainability.
Flow rate, density, pressure, temperature and superficial velocity determine sizing. Velocity must remain below the K-factor limit to prevent re-entrainment.
Flow rate, density, viscosity and droplet distribution influence selection; higher loads can favor vane packs, while low loads and fine mists suit mesh pads or coalescers.
Indicative ranges: mesh pads remove 5–10 μm droplets, vane packs capture 8–12 μm, and coalescers remove 1–5 μm aerosols.
Density difference, viscosity, surface tension and wetting behaviour affect capture efficiency and drainage.
Typical ranges: mesh pads 1–5 mbar, vane packs below 1 mbar, and coalescers 5–15 mbar.
Vane packs offer wider turndown; mesh pads suit stable loads, while coalescers have limited turndown due to drainage constraints.
Solids, wax or foam can favor vane packs. Fine mesh pads and coalescers may be unsuitable for fouling services.
Material selection considers corrosion, temperature and compatibility, including stainless steel, nickel alloys, plastics or thermoplastics.
Indicative heights: vane packs 150–300 mm, mesh pads 150–200 mm, and coalescers 300–600 mm.
Equipment and internals
Inlet devices manage momentum and phase distribution; downstream baffles and sand-jetting systems support stable, maintainable operation.
Liquid distribution
Single or matched transverse baffles distribute liquid from the turbulent inlet zone toward the calmer separation zone.
Liquid distribution
Plate diameter, hole diameter, pitch and open-area ratio inform the sizing of perforated distribution baffles.
Solids management
Fixed nozzles in a grid or ring mobilize and flush sand deposits while design checks help avoid erosion.
Solids management
A swirl-type jetting arrangement for directing wash flow across settled solids in separator vessels.
Inlet device
Vane geometry helps dissipate inlet momentum and distribute flow within the vessel.
Inlet device
A compact cyclonic arrangement for inlet flow conditioning and phase disengagement.
Jetting fluid velocity and pressure, nozzle sizes, number and spacing, and jetting-water flow rates are considered to support effective cleaning and separator uptime.
Gas-phase polishing
GSD provides mesh-pad demisters, vane-type mist eliminators, including Chevron-style designs, and liquid coalescers to remove entrained droplets. Materials include metals, plastics and thermoplastics to suit a range of process applications.
Discuss Internals Selection
Flow visualization
Local CFD clips illustrate gas filtration and phase-velocity behaviour in process equipment.
Experience across the industry











Share your process conditions and design requirements with our engineering team.